Specifications | |
Range: | XP88: 8" to 24.6' (20cm to 7.5m) XP89: 8" to 32.8' (20cm to 10m) |
Accuracy: | ± 0.2% of max. range |
Resolution: | 0.079" (2mm) |
Beam width: | 3" (7.6cm) dia. |
Dead band: | 8" (20cm) |
Display type: | LCD, 6-digits |
Display units: | inch, cm, percent, feet or meter |
Memory: | Non-volatile |
Supply voltage: | 18-28 VDC (loop) |
Loop resistance: | 250 Ohms max @ 24 VDC |
Signal output: | 4-20 mA, two-wire |
Signal invert: | 4-20 mA or 20-4 mA |
Calibration: | Push button (3-button) |
Fail-safe: | 4 mA, 20mA, 21 mA, 22 mA or hold last |
Process temp.: | F: -4° to 140° C: -20° to 60° |
Temp. comp.: | Automatic |
Electronics temp.: | F: -40° to 160° C: -40° to 71° |
Pressure: | 30 psi (2 bar) |
Enclosure rating: | NEMA 4X (IP65) |
Enclosure mat.: | Aluminum |
Window mat.: | Glass |
Transducer mat.: | PVDF |
Process mount: | 2" NPT |
Conduit entrance: | Dual, 1/2" NPT |
Mount gasket: | Viton® |
Compliance: | RoHS |
Classification: | Explosion Proof |
Approvals: | FM:Class I, Div I Groups A, B, C, D Class II/III, Div I, Groups E, F, G |