ECG database player

參   考   價(jià): 1000

訂  貨  量: ≥1 個(gè)

具體成交價(jià)以合同協(xié)議為準(zhǔn)

產(chǎn)品型號(hào)MECG2.0

品       牌其他品牌

廠商性質(zhì)代理商

所  在  地上海市

更新時(shí)間:2024-09-26 08:17:14瀏覽次數(shù):516次

聯(lián)系我時(shí),請(qǐng)告知來自 化工儀器網(wǎng)
同類優(yōu)質(zhì)產(chǎn)品更多>
應(yīng)用領(lǐng)域 醫(yī)療衛(wèi)生,生物產(chǎn)業(yè),電子/電池,航空航天,綜合
ECG database player, MECG 2.0 designed for system validation and software algorithm evaluation. Suitable for R&D and compliance testing. Compliant with IEC 60601-2-25

ECG database player, MECG 2.0

The ECG database player designed for system validation and software algorithm evaluation. Suitable for R&D and compliance testing.

Compliant with IEC 60601-2-25, IEC 60601-2-47, ANSI / AAMI EC57, YY0782 and YY0885.

OVERVIEW

Load and replay multi-channel ECG waveforms for diagnostic and ambulatory ECG

Output analog signals simultaneously up to 8 channels and support 12 lead ECG

Embedded CAL, ANE, NST and biological waveforms

Directly support AHA, MIT, CU, NST, ESC and PhysioNet format databases

Support digital file playback function for user to repeatedly play clinical-recorded or programmed waveforms

Extreme output voltage resolution - 0.15μV for MECG 2.0 (2020)

Command replay function enables to program test sequences with commands

Software Development Kit (SDK) allows to develop customized or automated test software with less efforts


SPECIFICATION

ItemsDetails / ReferenceValues

Output channelsThe 8 output channels are provided through a network as specified in IEC 60601-2-51 to provide signals to 10 lead electrodes; in the device under test, this will be displayed as 12 leads.8 outputs

10 lead electrodes

12 leads

Voltage accuracyIEC 60601-2-51 specifies a limit of ±1%, but does not provide a lower limit (all systems must have a lower limit). An inferred specification of 1% ±5µV is derived from the device under test specification in IEC 60601-2-51 of 5% ±25µV.For MECG 2.0, ±1% for values greater or equal to 500μV and ±5μV for values under 500μV.

For MECG 2.0 (2020), ±1% for values greater or equal to 100μV. ±5μV for values under 100μV.

Output voltage resolutionMECG 2.0 uses 12 bit DAC and MECG 2.0 (2020) uses 16 bit DAC.MECG 2.0 for 2.4μV and MECG 2.0 (2020) for 0.15μV

Output voltageThe output voltage on most of the database and ECG is +5mV~-5mV.±5mV

Output noise

level 0-150HzOutput noise should not influence the test. A value a 5µV is suitable for this requirement. Can be verified by monitoring the signal in the device under test using a “diagnostic" filter setting.<5µV

Time accuracyIEC 60601-2-51 does not provide any limits. An inferred limit from the device under test. An inferred limit of ±1% is used. The system’s design accuracy exceeds 0.1% as a 100ppm crystal reference is used.±1%

Sampling rateA maximum sampling rate of 1kHz matches the sampling rates of ECG files.1kHz (8 channels)

Power supplyPowered from the USB supply (5V 0.2A)N/A

EnvironmentIntended for normal laboratory environment. The selection of critical components such as reference voltages, DAC, precision resistors are known to be stable in the range shown.15 - 30°C

10 - 95% RH


外形尺寸: 16.5cm(長)*9.8cm(寬)*4.2cm(高),接線盒尺寸:13.5cm(長)*17.5cm(寬)*4.5cm(高)




會(huì)員登錄

×

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
撥打電話
在線留言
武功县| 泰兴市| 阳高县| 汉中市| 青田县| 许昌市| 仙游县| 抚远县| 黄大仙区| 宁南县| 青铜峡市| 江永县| 太康县| 西乌珠穆沁旗| 永吉县| 富平县| 哈尔滨市| 团风县| 城固县| 宜兰县| 车致| 彰武县| 辽宁省| 黑山县| 夏邑县| 陕西省| 同仁县| 读书| 晋中市| 克拉玛依市| 柳林县| 板桥市| 平远县| 临朐县| 汤原县| 永德县| 松滋市| 磴口县| 孟州市| 壶关县| 定南县|