本頁面標(biāo)準(zhǔn)信息均來源于網(wǎng)絡(luò)收集,或由參與標(biāo)準(zhǔn)制定的供應(yīng)商提供,只作為參考使用,為確保測(cè)試結(jié)果的準(zhǔn)確性、節(jié)省您的時(shí)間,如需EDS-T-7415標(biāo)準(zhǔn)詳細(xì)信息或EDS-T-7415具體測(cè)試方法,請(qǐng)與我們技術(shù)人員聯(lián)系或給我們留言,我們將為您提供相關(guān)的技術(shù)支持。

 

1.PRPOSE

This standard aims at specifying the method of evaluating colorfastness to artificial light of dyes, prints, paints and trim materials (textiles, genuine leather, artificial leather, plastics, cardboard, wood etc.) by exposing them to the artificial light similar to the natural light under a specific temperature.

2.SOCPE

Measurement of the color fastness to artificial light of various materials

3.DEFINITION

3.1. Color fastness to artificial light : It is a measure of the resistance of the colorants (dyes, pigments etc.) of materials to the effects of light and heat,

4.TEST PIECES AND NMBERS OF TEST PIECES

4.1. Take test pieces of 70 X 220mm from the finished products or from the raw material so that the color and shape of the finished product is maintained. For textile, take the sample along warp thread and mount it on the test holder.

4.2. Test pieces for multiple exposure test shall be tested being backed by another material like polyester fleece.

The back of the test piece holder shall always be sealed. nless specified otherwise, the thickness of such backing shall not be smaller than 5mm.

4.3. Threads or yarns shall be tightly wound around the cardboard and have the same dimensions as the test piece holder when tested.

4.4. For thick or backed-up test pieces, the difference between the distance from the light source to the surface of the test piece and that from the light source to the blue standard cloth for color fastness test or black panel thermometer surface shall not exceed 5mm.

4.5. For initial sample approval and for routine quality control, at least one test piece shall be tested. When specific requirements are not met in the test for arbitration purposes, the test shall be repeated with at least one test piece.

5.CONDITIONING

Tests shall be performed in the as received condition without any special pre-conditioning.

6.TEST EQIPMENT

6.1.  Light source, filter system and test apparatus
Test equipment permitting mounting of one or more xenon arc lamps as the light source. The light radiated from the lamp is filtered by the optical filter system, such as the absorption filter or absorption-reflection filter. Regardless of the type of the filter system, the radiant energy to be applied to test pieces shall conform to the requirements in Table l.

EDS-T-7415測(cè)試儀器

* The discrepancies between the irradiation intensity applied to the test piece and that to the blue standard cloth for color fastness test shall not exceed 10%. Table 2 shows the optical filter system to be used.

6.1.1. Absorption filter system

(1) Air-cooled xenon arc lamp test equipment (Ex: Xenotest 450 / Xenotest alpha)

The xenon arc lamp and filter system are cooled by air flow. As ozone is generated during the test, it shall be ensured that ventilation of air is carried out outside the laboratory. nless otherwise specified, the burner for the lamp shall be replaced after 1500 0perating hours and filters shall be replaced after operation for the period specified by the manufacturer. The black panel thermometer shall be installed in the same position as the test piece and black standard temperature shall be adjusted according to Table 2.

(2) Water-cooled xenon arc lamps test equipment (Ex. Atlas Weather-O-meter Ci35 0r Ci65).

It is equipped with the water-cooled xenon arc lamp of adjustable wattage. Drop of irradiation intensity acting on the test piece surface resulting from aging of the lamp and filter system can be compensated for by increasing wattage of the xenon arc lamp. The lamp burner must be replaced when the desired irradiation intensity is no longer attainable. The test equipment without wattage control function shall be replaced after 1500 0perating hours. The black panel thermometer shall be installed in the same position as the test piece and black standard temperature shall be adjusted according to Table 2.

6.1.2. Absorption-Reflection filter system (Ex: Xenotest 1200)

(1) The system is cooled by air flow and ozone is not generated. The burner shall be replace after 1500 operating hours. As irradiation intensity drops after 500 hrs from burner replacement, wattage shall be adjusted

accordingly. The filter system partly made of the glass shall be replaced after operation for the period specified by the manufacturer. The black panel thermometer shall be installed in the same position as the test piece and black standard temperature shall be adjusted according to Table 2.

6.1.3. Black panel thermometer

The black panel thermometer, which indicates the surface temperature of the test piece in the test equipment, consists of a plain metal plate with a high heat transfer rate (70mm x 40mm, 0.5 t) and a thermometer attached to its back. The metal plate is attached to a plastic panel for thermal isolation from the source of radiation. The surface of the metal plate, which is coated in black, absorbs over 95% of infrared rays.

6.1.4. Gray scale

sed for evaluating discoloration of the test piece after color fastness test, It is a standard gray scale made of up of 5 grades.

6.1.5. Blue standard cloth for color fastness test (standard fabric approved by standards such as JIS L 0841) A series of blue wool fabric specially dyed to represent different color fastness, it is classified from grade l t0 8 depending on the color fastness. (Grade l standard cloth has the lowest color fastness and grade 8 standard

cloth has the highest color tastness). It permits comparison of color fastness regardless of the type, working method, color shade or color intensity of the part or material

6.1.6. Standard cloth for humidity adjustment Cotton fabric dyed with red azoic dye

6.1.7. Stamping device, scissors and cutter for test piece preparation

6.1.8. The test for arbitration and overlap exposure test shall be conducted under the same conditions using the same equipment (Xenotest 450 / Xenotest alpha in clause 6.1.1. (1》.

6.2. Test conditions

The test pieces and blue standard texture shall be exposed to the same light source inside the test equipment and temperature and humidity shall conform to Table 2.

EDS-T-7415測(cè)試條件

7.PROCEDRE

7.1. Arrange the test piece according to clause 4 and install it onto the test equipment using the holder and then expose the blue standard texture to the light source according to test conditions in Table 2.

7.1.1. Method A (Code A)

This method is used to determine color fastness of the test piece for which no information on color change is available. A piece of blue standard cloth is needed for each test piece.

(1) Shield some l/3 0f the test piece and blue standard cloth with covers longitudinally and expose them to the light source according to Table 2 and then regularly examine the test piece to confirm discoloration.

(2) Remove the cover regularly and examine the test piece until the color difference between the exposed and unexposed portions of the grade 4 blue standard cloth corresponds to grade 4 0f the gray scale.

(3) Move the cover so that some l/2 0f the test piece is shielded longitudinally and expose it again to the light source. Stop the test until the color difference between the exposed and unexposed portions of the

grade 6 standard blue cloth becomes noticeable (corresponding to Grade 3 0n the gray scale).

(4) Compare the color difference of grade 7 blue standard cloth with the gray scale to determine the color fastness of the test piece (roughly between 7,7 ~8,8). If the color difference of grade 7 blue standard cloth corresponds to grade 4~5 0n the gray scale, the color fastness of the test piece is grade 7~8. If there is no color difference between the test piece and blue standard cloth, the color fastness of the test piece is grade 8.

7.1.2. Method B (Code B)

This method is used to see if the test piece meets the requirements in drawings or material specifications when such are specified.

(1) Shield some l/2 0f the test piece and blue standard cloth with covers longitudinally and expose them to the light source according to Table 2 and then regularly examine the blue standard cloth to adjust intensity of exposure.

(2) Stop the test when the color difference between the exposed and unexposed portions of the blue standard cloth of the specified grade is the same as the grade 4 0n the gray scale. Compare the color difference between the exposed and unexposed portions of the test piece with grade 4 0n the gray scale for evaluation.

7.1.3. Method C (Code C)

This method is used to evaluate surface change and physical properties/performance change as well as color change, after overlap exposure test. The number of exposure cycle shall be specified separately.

(1) Expose the test piece and blue standard cloth to the light source according to Table 2.

(2) End the exposure cycle when the color difference between the exposed and unexposed portions of the grade 6 standard blue cloth corresponds to Grade 3 0n the gray scale. Repeat for the specified exposure cycles. (se a new blue standard cloth for each cycle.)

(3) Duration ot exposure cycle may vary depending on the irradiation energy applied o test piece.

7.1.4. Method D (code D)

This method is used for testing the material which is deformed under conditions of method B. Test equipment is under the same conditions as method B except that the test piece and blue standard cloth are inserted to the holder and the holder with the test piece on is turned 1800 around the longitudinal axis of the holder for each turn of the holder supporter.

7.1.5. If the test method, exposure conditions, etc. are not specified on the drawings or material specifications, perform -B3- test.

8.EVALATION

8.1. Test according to method A, B and D

The color fastness of a test piece is the specific grade of a blue standard cloth whose color difference betweenthe exposed and unexposed portions is the same as grade 4 0r 3 0n the gray scale. Evaluate the test piece

until the color difference between the exposed and unexposed portions of the blue standard cloth of grade 7 corresponds to grade 4 and 3 0n the gray scale. When the color difference of the test piece comes in between two specific grades of the blue standard cloth, express it by the two grades with a dash inserted (Ex. grade 3 ~4). If the color difference is grade 3 0r above on the gray scale, perform the test again.

8.2. Test according to method C,

After completing the specified exposure cycle according to the characteristic values on drawings and material specifications, evaluate the test piece as follows:

8.2.1. Surface (Ex : gloss, crack and blister)

8.2.2. Physical properties and performance (Ex : tensile strength, abrasion, hardness)

8.2.3. Color change : visual check according to a gray scale

9.EXPRESSION OF RESLTS

The color fastness to artificial light shall be expressed by the grade according to the evaluation method in clause 8 (characteristic values included for tests according to method C), Record the apparatus used for the test in the test certificate or report.

10.CODING

The color fastness to artificial light is expressed as follows:

光照色牢度表示

Designation Test method Detailed test method (clause 7) exposure (table 2) Requirements

Deviations from the requirements of this test method (e.g. black panel temperature etc.) shall have been agreed upon. Such deviations shall be specified in material specifications, drawing etc. and indicated in test certiticates, reports etc.

EDS-T-7415 ('91.7) : Method for determining color fastness to xenon arc light, etc

免責(zé)聲明

  • 凡本網(wǎng)注明“來源:化工儀器網(wǎng)”的所有作品,均為浙江興旺寶明通網(wǎng)絡(luò)有限公司-化工儀器網(wǎng)合法擁有版權(quán)或有權(quán)使用的作品,未經(jīng)本網(wǎng)授權(quán)不得轉(zhuǎn)載、摘編或利用其它方式使用上述作品。已經(jīng)本網(wǎng)授權(quán)使用作品的,應(yīng)在授權(quán)范圍內(nèi)使用,并注明“來源:化工儀器網(wǎng)”。違反上述聲明者,本網(wǎng)將追究其相關(guān)法律責(zé)任。
  • 本網(wǎng)轉(zhuǎn)載并注明自其他來源(非化工儀器網(wǎng))的作品,目的在于傳遞更多信息,并不代表本網(wǎng)贊同其觀點(diǎn)和對(duì)其真實(shí)性負(fù)責(zé),不承擔(dān)此類作品侵權(quán)行為的直接責(zé)任及連帶責(zé)任。其他媒體、網(wǎng)站或個(gè)人從本網(wǎng)轉(zhuǎn)載時(shí),必須保留本網(wǎng)注明的作品第一來源,并自負(fù)版權(quán)等法律責(zé)任。
  • 如涉及作品內(nèi)容、版權(quán)等問題,請(qǐng)?jiān)谧髌钒l(fā)表之日起一周內(nèi)與本網(wǎng)聯(lián)系,否則視為放棄相關(guān)權(quán)利。
企業(yè)未開通此功能
詳詢客服 : 0571-87858618
沁阳市| 蒙城县| 贡觉县| 红安县| 水城县| 铜川市| 廊坊市| 南皮县| 北票市| 洪江市| 沂源县| 莫力| 上饶县| 香港 | 罗定市| 理塘县| 都昌县| 得荣县| 和平区| 枝江市| 大埔县| 威远县| 八宿县| 田东县| 峨眉山市| 育儿| 和林格尔县| 奉节县| 扶风县| 突泉县| 汾西县| 彭水| 巴青县| 凌云县| 建宁县| 葫芦岛市| 班戈县| 铜鼓县| 米脂县| 句容市| 兰考县|